Millar clinical pressure-volume (PV) catheters combine pressure sensors and electrodes for simultaneous high-fidelity pressure, volume and intracardiac ECG measurements, enabling minimally invasive, continuous, intracardiac pressure-volume analysis.
PV models feature a high torque catheter body and range in size from 5 to 6 French in single-field or dual-field configurations, with non-functional pigtails. Model configurations include the availability of a second pressure sensor and up to 12 electrodes. Electrode spacing varies to accommodate a range of applications.
Millar also offers pressure-volume catheters configured for an apical approach.
Pressure-Volume Loops
Parameters include: |
Pressure-Volume
Applications |
- Contractility index (ESPVR)
- Elastance (EDPVR)
- Cardiac output
- Stroke volume
- Maximum and minimum
ventricular dP/dt
- Pre-load recruitable
stroke work (PRSW)
- Ejection fraction
|
- Baseline PV loop analysis
- Occlusion PV loop analysis
- Phenotyping gene manipulations
- Cardiac hypertrophy
- Cardiac failure
- Cardiovascular remodeling
- Toxicology
- Pharmacology (rapid drug screening)
- Cardiac resynchronization therapy
- Surgical interventions
- Ischemia/reperfusion studies
- Vascular occlusions
|
Reusable Pressure-Volume Catheters
- Simultaneous high-fidelity pressure, volume and intracardiac ECG measurements
- 5 or 6 French, straight or pigtail catheter tip
- Re-sterilization with ethylene oxide (ETO) gas
- Up to 7 volume segments and option for multiple pressure sensors
Click here for a detailed product table.
Click on product model name for more details.
Model Number |
Material |
Length |
Tip French |
Number of Sensors |
Sensor Location |
Electrode Spacing |
No. of Electrodes |
Tip |
Pigtail |
Pressure Connector |
Use Life |
Repairable |
|
SPC-550-2 |
Nylon |
125 cm |
5 F |
1 |
Between E4 & E5 |
9 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-550-3 |
Nylon |
125 cm |
5 F |
1 |
Between E4 & E5 |
12 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-550-4 |
Nylon |
125 cm |
5 F |
1 |
Between E4 & E5 |
15 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-550-5 |
Nylon |
125 cm |
5 F |
1 |
Between E5 & E6 |
7 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-550-7 |
Nylon |
125 cm |
5 F |
1 |
Between E5 & E6 |
10 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-550-8 |
Nylon |
125 cm |
5 F |
1 |
Between E4 & E5 |
7 mm |
8 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-560-1 |
Polyurethane |
125 cm |
6 F |
1 |
Between E4 & E5 |
7 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-560-2 |
Polyurethane |
125 cm |
6 F |
1 |
Between E3 & E4 |
9 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-560-3 |
Polyurethane |
125 cm |
6 F |
1 |
Between E4 & E5 |
12 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-560-4 |
Polyurethane |
125 cm |
6 F |
1 |
Between E4 & E5 |
15 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-560-7 |
Polyurethane |
125 cm |
6 F |
1 |
Between E5 & E6 |
10 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
|
SPC-562-1 |
Polyurethane |
125 cm |
6 F |
2 |
Between E4 & E5, 5 cm > 12 |
7 mm |
12 |
Straight |
Pigtail |
Low Profile |
Non-Sterile, 5 Use Limit |
No |
Accessories
- Connection cables
- Delta-cal pressure transducer tester
For more information on Millar clinical pressure-volume (PV) catheters or to purchase, call 832.667.7000 or complete our contact form.