Pressure Control Units & Accessories

Millar offers a selection of Pressure Control Units and cables for interfacing Millar Mikro-Tip catheter pressure transducers with existing clinical cath lab monitors and data acquisition systems. Our pressure control unit models output multiple reference voltages for quick calibration and provide dynamic zero balancing of the pressure signal.

A close up loo at a computer screen with graphs and data

Control Units Provide Interface Connection

When purchasing a Millar Mikro-Tip blood pressure catheter, one of these pressure control units is required to interface with clinical lab systems: the TC-510 Pressure Control Unit or the PCU-2000 Pressure Control Unit with Patient Isolation.

TC-510 Pressure Control Unit

The TC-510 Pressure Control Unit is a passive interface between the Millar Mikro-Tip catheter pressure transducer and clinical cath lab systems. This model requires connection to either an integrated or standalone bridge amplifier. Strain gauge pressure monitors supply bridge excitation voltage and have balance and calibration controls for full-bridge strain gauge pressure transducers. The TC-510 has an internal calibration circuit to provide an electrical zero as well as a 100 mmHg calibration signal. The output connector is a standard 9-pin sub-D. A separate monitor interface cable is required.

The TC-510 Pressure Control Unit has been designed to be used only with monitors that supply patient isolation.

A product shot of the TC-510 Pressure Control Unit on a graphic background

Product Specifications

Product Reference 851-5918
Isolated Input/Output No
Input Connector Viking
Output Connector 9 Pin DIN
Passive/Active Passive
Sensor Sensitivity 5 µV/V/mmHg, nominal (37.6 µV/V/kPa)
Power External Bridge Amp
Repairable Yes
Compatible Cable Millar TEC-10D cable featuring a low profile catheter connector and Viking control unit connector. The cable length is 10 ft (305 cm).

PCU-2000 Pressure Control Unit with Patient Isolation

The PCU-2000 Pressure Control Unit is a two-channel, patient-isolated, line-powered bridge amplifier for connecting one or two single-sensor Millar Mikro-Tip catheters to a clinical patient monitor or standalone data acquisition system. The unit provides built-in ridge excitation eliminating the need for a separate bridge amplifier. Each channel has an electrically isolated input for patient safety.

The analog output signal level of 1V/100 mmHg is compatible with most pressure monitors and data acquisition systems. The in-line power supply adapts automatically to line voltages from 100 to 240 volts AC. Its power cord is long enough to allow the power supply to be positioned well outside the field of operation.

A product shot of the PCU-2000 Pressure Control Unit with Patient Isolation on a graphic background

Product Specifications

Product Reference 880-0129
Isolated Input/Output Yes
Input Connector Redel
Output Connector 1/4'' Phono Jack
Passive/Active Active
Power Line Powered
Repairable Yes
Compatible Cable Millar PEC-10D cable featuring a low profile catheter connector and Redel control unit connector. The cable length is 10 ft (305 cm).

ADInstruments PowerLab & LabChart Designed for Precision Data Acquisition & Analysis

PowerLab is a data acquisition (DAQ) device engineered for precise, consistent, reliable data acquisition. Capable of recording at speeds of up to 400,000 samples per second continuously to disk (aggregate), PowerLabs are compatible with instruments, signal conditioners, and transducers supplied by ADInstruments and others. Built for precision, research PowerLabs are engineered to provide high quality, reproducible data while meeting the strictest international safety standards.

LabChart Pro Analysis Software by ADInstruments

LabChart data analysis software creates a platform for all your recording devices to work together, allowing you to acquire biological signals from multiple sources simultaneously and apply advanced calculations and plots as your experiments unfold. With LabChart analysis software, you can record and display up to 32 channels of data in real time, performing online calculations at high sampling rates, giving you full control of your research.

Learn More at ADInstruments

Millar Control Units and Accessories Support OEM Pressure Integration Testing

Combine the Millar PCU-2000 Pressure Control Unit, an 8-channel ADInstruments PowerLab Data Acquisition System and LabChart Pro Analysis software with our OEM MEMS sensors or modules to test pressure sensor integration with your medical device development projects.

Get More Info

Contact Millar

Contact Millar today to find out more about our Pressure Control Unit Models or to request a quote. We welcome your questions. US Headquarters T: +1 832.667.7000. Toll Free: 800.669.2343 (US Only)

Contact a Sales Rep

Back
to Top