Cardiovascular Pressures

A vital signs monitor showing a patient’s vital signs during an operation.

Deeper Insights into Cardiovascular Function

Millar’s Mikro-Cath® Pressure Catheter delivers true hemodynamic data for deeper insight into cardiovascular function, helping guide diagnostic decisions when precise measurements count. Mikro-Cath data from the source provides reliable signals, including accurate dP/dt for advanced clinical applications, such as exercise studies, drug therapy evaluation and heart failure cases.

Mikro-Cath Cardiovascular Applications

A Millar employee carefully works on a Mikro-Cath pressure catheter.

Left Ventricular Pressures

Mikro-Cath provides direct ventricular pressure measurements for clearer waveform analysis — especially useful when noninvasive diagnostics are inconclusive, such as in constrictive pericarditis.

Close-up of a patient wearing a clear respiratory mask, representing the clinical application of advanced medical technology,

Pulmonary Artery Pressures

Mikro-Cath delivers a more accurate and reproducible Pulmonary Artery Pressures (PAP) waveform, independent of the factors that impact fluid-filled readings, simplifying both the recording and reading of PAP-derived parameters.

Millar clinician reviewing live imaging and cardiovascular pressure data from a Mikro-Cath catheter during Cardiac Resynchronization Therapy (CRT) to optimize lead placement in real time.

Cardiac Resynchronization Therapy

Mikro-Cath records precise measurements of cardiovascular function. This high-fidelity pressure data, in conjunction with imaging technologies, provides clinicians an opportunity to optimize lead placement in real time.

Mikro-Cath Catheter Versus Traditional Fluid-Filled Catheters

Mikro-Cath Pressure Catheters use Millar’s patented pressure sensor technology to record precise measurements of cardiovascular function, unaffected by motion artifacts or body position. This high-fidelity pressure data helps to identify potential cardiovascular conditions and make in-depth assessments in real time.

Clinicians can obtain more comprehensive and accurate measurements for:

  • Left Ventricular Pressures (LVP)
  • Right Ventricular Pressures (RVP)
  • Mean Arterial Pressures (MAP)
  • Valve Gradients
  • Radial Artery Pressures
  • Peripheral Lesion Pressure Gradients

With an appropriately sized guide catheter or introducer, the Mikro-Cath can be easily integrated into any cath lab’s hemodynamic system via standard interface cables, offering an immediate upgrade to the fluid-filled catheter.

When compared to fluid-filled catheters, the Mikro-Cath Pressure Catheter provides real-time, accurate blood pressure data. The Mikro-Tip® sensor measures blood pressure at the source, providing a true representation of the blood pressure waveform, and eliminates many of the common shortfalls of fluid-filled catheters, including signal variances from patient height or position changes.

MIKRO-CATHFLUID-FILLED
Accurate dP/dtUnreliable dP/dt
True pressure signalAugmentation of signal — overshoot, resonance
No time delayTime delay
Free from motion artifactsMotion artifacts — catheter whip
True pressure readings at any height in fluidGravitational effects on zero

Mikro-Cath: The Gold Standard in High-Fidelity Pressure Sensing

The Mikro-Cath Pressure Catheter delivers repeatable, exact data for reliable insight into cardiovascular, respiratory and intracompartmental pressure cases. The solid-state catheter is unaffected by motion artifacts or body position, providing data you can count on when making critical clinical decisions. Mikro-Cath also provides expert evaluation for benchtop studies when evaluating efficacy of medical device performance.

A close-up of Millar’s Mikro-Cath pressure catheter.

Learn More About Cardiovascular Pressures

Download the Mikro-Cath Pressure Catheter information sheet to learn more about Millar’s market-leading solution for obtaining the most accurate and comprehensive cardiovascular pressure measurements.

A doctor showing cardiovascular imagery to a patient in real time.

Connect with Our Medical Sales Team

Whether you’re testing new concepts in the lab or translating them to clinical care, our team is here to support your journey from innovation to implementation.