Supporting Medical Research with Sensing Technology

A medical researcher works with Millar’s MPVS Duo pressure volume loop measurement system.

Millar and ADInstruments: Partners in Research Excellence

With over 85 years of combined experience, Millar and ADInstruments are proud to partner in delivering world-class solutions for life science and medical research. As Millar’s exclusive global distributor, ADInstruments helps bring our gold-standard Mikro-Tip® catheter technology to researchers around the world. Together, we empower researchers, clinicians and developers to push the boundaries of discovery with unmatched precision, reliability and support.

Millar’s MPVS Duo Pressure-Volume Loop System device.

Pressure-Volume Loop Studies

Our market-leading Millar Pressure-Volume (PV) Loop System, the MPVS Duo™, simultaneously and continuously measures high-fidelity ventricular pressure and volume in real-time. The MPVS Duo system, in combination with our trusted Mikro-Tip catheters, delivers real-time data with pinpoint accuracy and precision across all animal models from transgenic mice to livestock. With this cutting-edge technology, researchers have comprehensive data at their fingertips, empowering them to make confident, informed decisions that drive groundbreaking discoveries.

A Millar pressure catheter.

Pressure Catheters

Millar Mikro-Tip high-fidelity pressure catheters provide an ideal solution for measuring highly accurate pressures, including arterial and ventricular blood pressures, spinal pressures, tumor pressures, or airway pressures. Our complete line of Mikro-Tip pressure catheters ranges in size from 6 F for larger animals to the world’s smallest 1 F catheter for mouse cardiac evaluation.

A Millar electrophysiology catheter.

Electrophysiology Catheters

Millar electrophysiology (EP) catheters support standard EP studies by applying pacing and recording protocols either intracardially or transesophageally to assess atrial and ventricular electrical properties. This is a proven method for characterizing the electrical phenotype of transgenic mice, as well as determining and diagnosing detrimental heart conditions.

Mikro-Tip Pressure Catheters
Header 1Header 2Header 3Header 4Header 5Header 6
SPR-1000MouseStraight1F116 cm
SPR-671MouseStraight1.4F116 cm
SPR-524Small MammalStraight3.5F1100 cm
SPR-350Pig and SheepCurved5F1120 cm
SPR-751Pig and SheepCurved5F2120 cm
Millar Products Used in Cardiac Pressure-Volume Loop Studies
ModelSubjectTIpTip F Size# of SensorsElectrode SpacingLength
SPR-839MouseStraight1.4F14.5 mm3.5 cm
PVR-1045MouseStraight1F14.5 mm3.5 cm
PVR-1035MouseStraight1F13.5 mm3.5 cm
PVR-1030MouseStraight1F13 mm3.5 cm
SPR-838RatStraight2F19 mm12.5 cm
SPR-869RatStraight2F16 mm12.5 cm
SPR-877Small MammalStraight3F12.5 mm120 cm
Ventri-Cath 507Pig and SheepPigtail or Straight5F17 mm120 cm
Ventri-Cath 510Pig and SheepPigtail or Straight5F110 mm120 cm
Ventri-Cath 512Pig and SheepPigtail or Straight5F112 mm120 cm
Ventri-Cath 515Pig and SheepPigtail or Straight5F115 mm120 cm

Get Precise Pressure Results

For more information on how Millar and ADInstruments are working together to provide precise pressure and pressure volume research results, please download the Accuracy Matters brochure.

Connect with ADInstruments

Ready to get the right device for your pre-clinical study? Contact ADInstruments for the right products and guidance you need to get started.