Left Ventricular Pressures

Surgeons at work during a cardiovascular operation.

Clearer Ventricular Waveforms in Challenging Cardiac Cases

Millar’s Mikro-Cath® Pressure Catheter provides a direct high-fidelity measure of left and right ventricular blood pressure, resulting in cleaner waveform tracings and easier identification of discordant systolic and diastolic values for comparison purposes. In constrictive pericarditis cases, in particular, noninvasive diagnostic results are often inconclusive, requiring invasive cardiac catheterization.

Evaluate Pericarditis Using Left and Right Ventricular Pressure Waveforms

Pericarditis is a condition in which the pericardium becomes inflamed. In some cases, scarring and thickening of the pericardium occurs, resulting in constrictive pericarditis, which can lead to long-term heart-failure-like problems. While noninvasive methods exist for diagnosing various pericardium conditions, at times the results are inconclusive, and invasive cardiac catheterization is necessary.

In these cases, fluid-filled transducers are generally used to measure left ventricular pressure and right ventricular pressure for comparison of LV and RV waveform areas during inspiration and expiration. In patients with constrictive pericarditis, these changes are discordant in that LV systolic pressure increases at expiration do not correlate with expected RV systolic pressure increases. LV systolic pressure decreases at inspiration show increases in RV systolic pressures.

The Mikro-Cath Pressure Catheter provides a direct high-fidelity measure of right and left ventricular blood pressure, resulting in cleaner waveform tracings and easier identification of discordant systolic and diastolic values for comparison purposes.

Left and right ventricular waveforms using Millar's Mikro-Cath Catheter.

In this example, a patient suspected of having constrictive pericarditis was catheterized with a Mikro-Cath for left ventricular pressure measurement and a fluid-filled transducer for right ventricular pressure measurement. Note the discordance in the LV and RV systolic pressures in the highlighted waveforms.

Mikro-Cath: The Gold Standard in High-Fidelity Pressure Sensing

The Mikro-Cath Pressure Catheter delivers repeatable, exact data for reliable insight into cardiovascular, respiratory and intracompartmental pressure cases. The solid-state catheter is unaffected by motion artifacts or body position, providing data you can count on when making critical clinical decisions. Mikro-Cath also provides expert evaluation for benchtop studies when evaluating efficacy of medical device performance.

Millar’s Mikro-Cath pressure catheter,
Millar’s Mikro-Cath pressure catheter,

Learn More About Left Ventricular Pressure

Download the application note to learn more about high-fidelity left ventricular pressure measurements.

Millar engineers working to continually assess and improve Millar’s Mikro-Cath pressure catheter.

Connect with Our Medical Sales Team

Whether you’re testing new concepts in the lab or translating them to clinical care, our team is here to support your journey from innovation to implementation.

Millar's leadership team meeting to support their clients journey from innovation to implementation.